Upgrade Notes

  • Update your boxes. All of this release’s fixes run on the box, except the gateway retry hint. Run lager update --box <box-name> after you upgrade the CLI.
  • FTDI GPIO channels behave differently. These changes affect every FTDI GPIO user:
    • A GPIO channel is never reset now, so a level stays set after the process that set it exits.
    • The serial tty of an FTDI channel used for GPIO disappears on first use and stays gone until the part is re-plugged. The ttys of other channels are not touched.
    • The output cache moved from /tmp/ft232h_gpio_cache.json to /etc/lager/ftdi_gpio_cache.json. The box moves the old file once.
    • After a power-up (a box reboot or a re-plug) the pins sit at the chip’s idle level, all HIGH, until something opens the channel. The saved levels come back on first use, not at boot.

Bug Fixes

  • A gateway’s “lager does not answer” now says to retry first. When a gateway answers 502 with X-Gateway-Error: upstream_unavailable, the CLI now says the box service may be restarting and suggests retrying in a few seconds. It suggests lager update or lager install only if the failure persists. A box service restarts itself in about 4 s to recover a USB device.
  • A /usb/command that restarts the service keeps the reason why. When a hub that would not open triggers the self-restart, the 503 restarting answer now carries the same reason_code and reason_detail as the 404 answer.
  • FTDI GPIO outputs hold their level after the process that set them exits. A level set from a lager python script, or by lager gpo before the next script started, used to fall back to HIGH on every pin of the channel, because each open and close reset the channel.
    • The driver no longer resets a GPIO channel.
    • lager gpi, lager nets state and Net.input() read output pins from the pin register, not a cached value.
    • Two nets on one channel no longer change each other’s direction.
    • Levels survive a box restart and a box reboot.
  • FTDI GPIO, I2C and SPI nets work again after the part is re-plugged. After an FTDI part re-enumerated (a lager usb <net> cycle, a power cut, a cable pull), lager gpo, lager gpi, lager i2c, lager spi and lager nets state failed with [Errno 19] No such device or No USB device with S/N ... until lager box-config restart. When an open fails because the box service’s USB device list is out of date, the drivers now refresh the list and open once more.

Installation

To install this version:
To upgrade from a previous version:
Then update your boxes:

Resources

View Release on PyPI