# Version 0.61.0

> October 30, 2026

## Upgrade Notes

* **Update your boxes.** Most of the fixes in this release run on the box. Run
  `lager update --box <box-name>` after you upgrade the CLI.
* **`lager wifi status` exits 1 when the box has no wireless interface.** It used to print
  "Interface detection failed" and exit 0. A script that treats that exit as success must
  now handle the failure.
* **`lager wifi status` and `lager wifi access-points` run on the box host over SSH.** They
  used to run inside the container, which cannot see the host's wireless interface.
  `access-points` now scans the box's own wireless interface by default, not `wlan0`.
* **`lager usb` on a YKUSH hub fails when a port does not switch.** The hub acknowledges a
  switch that it ignores, and `enable`, `disable`, `toggle` and `cycle` reported success. The
  driver now reads the port back. A script that relied on the false success now gets an error.

## Features

* **Yepkit YKUSH3 hubs are supported.** `lager instruments` and `lager nets add-all` detect
  the YKUSH3 (`04d8:f11b`). Its three USB ports are `usb` nets for `lager usb`. Its three GPIO
  pins are `gpio` nets for `lager gpi` and `lager gpo`. The hub's switchable 5V output is not
  a net.
* **The IPEVO V4K PRO document camera (`1778:d00e`) is detected as a webcam.** `lager
  instruments` lists it, and `lager nets add <name> webcam ...` accepts it.
* **A gated box's gateway can see which command each request belongs to.** Requests that carry
  a `lager login` token also send the command's name, such as `supply voltage`, with the CLI
  version and an id for the command. The name never includes arguments. A box that is not
  behind a gateway receives none of these headers.

## Bug Fixes

* **The `/scope` page shows the scope's real state.**
  * A Rigol that loses only its capture card is no longer called unplugged. The page says that
    the live view stopped, and it says when the card is back.
  * The page says when the box closes its connection after a long idle.
  * The run badge shows a dash after a disconnect. It used to keep its last state, such as
    TRIG'D, until the next frame.
  * The page says when a scope net has no channel nets, and it gives the `lager nets add`
    command for each channel.
  * The stream request no longer returns paths on the box when a scope's daemon fails.
* **The `/scope` page draws a Rigol's trace where the scope's own screen does.**
  * `display zoom` now magnifies the trace and shows the zoom bar.
  * A channel's hardware offset now moves its trace. The volts read off the trace do not change.
  * The box checks for a Rigol's side menu again a minute after a check finds none. The menu
    no longer stays over the live view.
* **A `stop` typed in the `/scope` page's console stops the measurement polling.** `start` and
  `start single` in the console now follow the same rule as their buttons.
* **`lager scope <net> cursor move-a` and `move-b` move from where the cursor is.** On a Rigol,
  each call started from the center of the grid. After `set-a --x -200`, `move-a --x 50` now
  puts A at -150, not +50.
* **`lager scope <net> status` says "running" for a Rigol that the daemon opens while it runs.**
  The command and the scope page said "stopped" after every daemon restart, power cycle or
  replug until you pressed Start.
* **`lager scope <net> measure` prints a reading without float noise.** A Rigol's duty cycle
  now prints as `49.987 %`, not `49.986999999999995 %`. A Rigol's refusal of an averaging count
  no longer names 65536 captures, which the CLI does not accept.
* **A Rigol MSO5000 bus decoder is refused before anything is sent.** Creating a UART, I2C, SPI,
  CAN or FlexRay decoder failed partway through the setup with "Function not found". It now
  raises an error that says the scope does not decode buses through lager.
* **The scope daemon's log says when the capture card stopped.** Requests that wait at that
  moment are no longer told that the oscilloscope stopped answering.
* **The scope daemon notices a PicoScope unplugged while it was idle.** The next command failed
  with a bare driver error. The daemon now closes the unit when a 2000-series call fails and no
  PicoScope is on the bus. It opens the unit again when it returns.
* **A PicoScope plugged back in gets its settings back.** Channel enables, volts/div, coupling,
  probe, timebase and trigger returned to the driver's defaults, so a page that pressed Start
  drew nothing. The same unit, by serial, now keeps its settings. A different unit starts from
  its defaults.
* **`lager debug flash` and `lager debug erase` no longer call an unreachable box too old.** With
  `--erase-start` or `--erase-size`, a `/health` timeout told you to update the box. The command
  now retries twice, then says that the box or its Stout gateway did not answer.
* **`lager diagnose` on a USB hub net reports an unreachable endpoint as unreachable.** It used to
  say that the box does not serve `/diagnose/usbhub`, and it told you to update the box.
* **`lager usb` says that the box service restarts, not "cannot reach box".** When a hub does not
  open after it re-enumerates, the box service exits to recover. It now answers first, and it
  tells you to retry in a few seconds.
* **Python API calls on a multi-channel supply net act on that net's channel.** On a Rigol DP800
  or Keysight E36000, `ovp()`, `ocp()`, `state()`, `clear_ovp()` and similar calls through
  `Net.get()` sometimes acted on another channel. `lager supply` was not affected.
* **`lager supply` can set OVP and OCP back to a Rigol DP800's factory limits.** A DP800 ships
  with protection limits up to 110% of the channel's rating, and the CLI refused any limit above
  the rating. The limit is now 110%. Voltage and current setpoints stay within the rating.
* **`wait_for_level()` on a LabJack T7 GPIO net counts the stream setup against its timeout.** A
  call ran about 30 ms past its timeout. The call still stops the stream before it raises
  `TimeoutError`, which can take about 0.6 s.
* **A command stopped with `kill` releases its box lock.** A killed background command, such as
  `lager debug <net> gdbserver`, used to hold its lock until the lock's TTL ran out.
* **The box's authorized\_keys sync survives the end of an install or update.** The key-sync
  poller now runs in its own session. A signal to the caller's process group no longer stops it.
* **The box image carries the license notices of uldaq and the LabJack Exodriver.** They are at
  `/usr/share/licenses/lager/vendor/`.

## Known Limitations

* **The YKUSH3 GPIO pins are not fully verified on hardware.** Their voltage level, and whether a
  written level is held, are not yet measured.
* **Two IPEVO V4K PRO cameras on one box share an address.** The camera reports no serial.
* **I2C and SPI per-call overrides stay on the driver.** An `overrides` value such as
  `frequency_hz` also applies to later calls on the same net. Set the value that you want on
  each call.
* **A failed resistance set on an EA solar net does not raise an error.** The call returns the
  resistance that the instrument still has. Compare the returned value with the value you set.

## Installation

To install this version:

```bash theme={null}
pip install lager-cli==0.61.0
```

To upgrade from a previous version: